Featured
Honya Biotech focuses on DNA/RNA Synthesizer, Pipetting and Elution Workstations, Deprotection Equipment, Amidite Dissolved Equipment, Purification Workstation, Synthesis Columns, Phosphoramidites, Modification Amidite, Synthesis Reagents, various consumables, etc, to provide you with the fastest and most efficient DNA/RNA synthesis products and services in the world.

Featured

  • OEM/ODM Supplier Rna And Dna Protein Synthesis - HY 12 DNA RNA Oligo Synthesizer for Medium synthesis – Honya

    OEM/ODM Supplier Rna And Dna Protein Synthesis - HY 12 DNA RNA Oligo Synthesizer for Medium synthesis – Honya

    Specification Synthesis scale 25nmol-300umol Cycle time 4-6 minutes Amidite bottle 12 (standard), it can expand to 20 sets Reagent bottle 9 sets Reagent position Single (Standard), it can expand to double bottle Waste liquid discharge Negative pressure with Vacuum pump Required gas   Nitrogen or Argon Optional Trityl Monitor Power single-phase 220V Working Temperature 25°C±4°C Relative Humidity within 45% Persistence operate continuously and normally Computer D...
  • 2022 High quality Laboratory Dna Synthesizer - HY 192 DNA RNA oligo synthesizer for high throughput – Honya

    2022 High quality Laboratory Dna Synthesizer - HY 192 DNA RNA oligo synthesizer for high throughput – Honya

    Specification Single channel synthesis scale 5nmol-1umole. Synthesis cycle time up to 6-8 minutes Synthesis cycle (20mer) 2-3 hours Phosphoramidite bottle base 8 sets Reagent bottle base 7 sets Base bottle 60/240/480ml screw mouth universal reagent bottle interface Auxiliary reagent bottle GL38 bottle mouth, use for universal 4L reagent bottles . Reagent driving method protective gas down pressure type Waste liquid discharge positive pressure Coupling rate 99% The ...
  • Low MOQ for Cpg Powder - Phosphoramidite Dissolving Equipment – Honya

    Low MOQ for Cpg Powder - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...
  • 2022 Good Quality Custom Oligonucleotide  - CPG Frit column with different size – Honya

    2022 Good Quality Custom Oligonucleotide - CPG Frit column with different size – Honya

    Specification Type Specifications No. Proe Size Package Frit Column 3nmol HY-H-8803 1000Å 1000 pcs/bag Frit Column 5nmol HY-H-8805 1000Å 1000 pcs/bag Frit Column 10nmol HY-H-8810 1000Å 1000 pcs/bag Frit Column 20 nmol HY-H-8820 1000Å 1000 pcs/bag Frit Column 50nmol HY-H-8850 1000Å 1000 pcs/bag Frit Column 100nmol HY-H-8100 1000Å 1000 pcs/bag Frit Column 200nmol HY-H-8200 1000Å 1000 pcs/bag ...
  • 2022 High quality 8 Channel Synthesizer - Phosphoramidite Dissolving Equipment – Honya

    2022 High quality 8 Channel Synthesizer - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...
  • Manufacturer for Long Oligos  - Bottle Caps for Phosphoramidite and Reagents – Honya

    Manufacturer for Long Oligos - Bottle Caps for Phosphoramidite and Reagents – Honya

    Phosphoramidite Bottle Cap It is used for Phosphoramidite bottle, there are two kinds of cap we can choose, Screw-top and bayonet bottles, customer can choose according to their requirements. No. HY-H832 Individually packaged MOQ: 1 Set Reagent Bottle Cap It is use for DNA RNA synthesis reagent, there are two tubes of the cap, one for air intake and the other for liquid output. No. HY-H833 Individually packaged MOQ: 1 Set FAQ 1. Are you a factory ...
  • Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya

    Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...
  • Original Factory Black Hole Quencher Dyes - Phosphoramidite Dissolving Equipment – Honya

    Original Factory Black Hole Quencher Dyes - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...
  • China wholesale Solid Phase Dna Synthesis - HY 192 DNA RNA oligo synthesizer for high throughput – Honya

    China wholesale Solid Phase Dna Synthesis - HY 192 DNA RNA oligo synthesizer for high throughput – Honya

    Specification Single channel synthesis scale 5nmol-1umole. Synthesis cycle time up to 6-8 minutes Synthesis cycle (20mer) 2-3 hours Phosphoramidite bottle base 8 sets Reagent bottle base 7 sets Base bottle 60/240/480ml screw mouth universal reagent bottle interface Auxiliary reagent bottle GL38 bottle mouth, use for universal 4L reagent bottles . Reagent driving method protective gas down pressure type Waste liquid discharge positive pressure Coupling rate 99% The ...
  • Factory source Cap A - Phosphoramidite Dissolving Equipment – Honya

    Factory source Cap A - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...
  • 18 Years Factory Rna - HY Single Channel Synthesizer for large scale – Honya

    18 Years Factory Rna - HY Single Channel Synthesizer for large scale – Honya

    Specification Synthesis scale  500nmol-7mmol Amidite bottle  8 sets Reagent bottle 7 sets Cycle Time 6-8minutes Power  Single-phase 220V. Working Temperature  25°C±4°C Relative Humidity     Within 45% Persistence   It can operate continuously and normally Weight 40kg     Size 500×500×700mm Warranty 1 year Advantage Feature 1. The innovative use of the stirring function of filler and reagents effectively shortens the reaction time and improves the ...
  • OEM Supply Deprotection Machine - Phosphoramidite Dissolving Equipment – Honya

    OEM Supply Deprotection Machine - Phosphoramidite Dissolving Equipment – Honya

    Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...