Featured
-
Chinese wholesale Dna Rna And Protein Synthesis - HY 12 DNA RNA Oligo Synthesizer for Medium synthesis – Honya
Specification Synthesis scale 25nmol-300umol Cycle time 4-6 minutes Amidite bottle 12 (standard), it can expand to 20 sets Reagent bottle 9 sets Reagent position Single (Standard), it can expand to double bottle Waste liquid discharge Negative pressure with Vacuum pump Required gas Nitrogen or Argon Optional Trityl Monitor Power single-phase 220V Working Temperature 25°C±4°C Relative Humidity within 45% Persistence operate continuously and normally Computer D... -
2022 New Style Molecular Biology Lab Reagents - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per... -
Professional China Sequence - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per... -
18 Years Factory Rna - HY 12 DNA RNA Oligo Synthesizer for Medium synthesis – Honya
Specification Synthesis scale 25nmol-300umol Cycle time 4-6 minutes Amidite bottle 12 (standard), it can expand to 20 sets Reagent bottle 9 sets Reagent position Single (Standard), it can expand to double bottle Waste liquid discharge Negative pressure with Vacuum pump Required gas Nitrogen or Argon Optional Trityl Monitor Power single-phase 220V Working Temperature 25°C±4°C Relative Humidity within 45% Persistence operate continuously and normally Computer D... -
Factory best selling Cyanine 5 Phosphoramidite - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per... -
China OEM Workinstation - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per... -
2022 Good Quality Hplc Purification - Elution Equipment use for wash nucleic acid – Honya
Feature Fully automatic Liquid beating and pumping. The beating sequence and beating volume are freely programmable, which can define the process freely. Optional 8-lane pipette, which can meet the whole row transfer of primers during purification. Optional shaking and reaction plate heating. Specification 1. A row of 8 playing liquid holes, can play liquid at the same time, the key playing liquid holes can play liquid alone. 2. Multiple reagent bottle positions can be con... -
2022 wholesale price Custom Lab Workstations - Full Automatic Pipetting Workstation with liquid transfer – Honya
Feature 1. The workstation can monitor the whole process of suction and injection in real time by setting parameters in order to discover abnormalities such as less suction, leakage and clot blockage in the process of suction and discharge, and correct them by corresponding treatment procedures. 2. The workstation adopts foreign imported suction device, which can realize the characteristics of high precision and one tip with multiple heads. 3. Compact in size, versatile in function and a... -
Well-designed Pyrazole Phosphoramidite Dna Synthesis - HY 12 DNA RNA Oligo Synthesizer for Medium synthesis – Honya
Specification Synthesis scale 25nmol-300umol Cycle time 4-6 minutes Amidite bottle 12 (standard), it can expand to 20 sets Reagent bottle 9 sets Reagent position Single (Standard), it can expand to double bottle Waste liquid discharge Negative pressure with Vacuum pump Required gas Nitrogen or Argon Optional Trityl Monitor Power single-phase 220V Working Temperature 25°C±4°C Relative Humidity within 45% Persistence operate continuously and normally Computer D... -
Professional China Oligosynthesis - Modified Amidite CPG for Oligo synthesis – Honya
Fluorescent Dyes No. Name Molecular weight Package Structural formula A8001-100/250 5′-Fluorescein CE Phosphoramidite (6-Fam Amidite) 843.95 100mg /250mg A8002-1000 3′-(6-Fluorescein) CPG (C3-Fam CPG) N/A 1g A8003-100/250 5′-Hexachloro-Fluorescein CE Phosphoramidite (6-HEX Amidite) 1050.61 100mg/250mg Cyanine Dyes No. Name Molecular weight Package Structural formula C6001-100/1000 3’-Cy3-CPG N/A 100mg/1g C6002-100/1000 3’-Cy5-... -
Ordinary Discount Dmt-Dg(Dmf)-Phosphoramidit - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per... -
High reputation Biosynthesis Of Nucleic Acid - Phosphoramidite Dissolving Equipment – Honya
Five Channel Introduction It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis per...