Factory Outlets Cpg Frit Column - Phosphoramidite Dissolving Equipment – Honya

Application:


Product Detail

Product Tags

Related Video

Feedback (2)

With a sound business credit, excellent after-sales service and modern manufacturing facilities, we have earned an excellent reputation among our customers across the world for Hplc Oligo Purification, Custom Dna Synthesis, 6 Channel Synthesizer, As a leading manufacture and exporter, we appreciate a great status inside the international markets, especially in America and Europe, because of our top high-quality and sensible charges.
Factory Outlets Cpg Frit Column - Phosphoramidite Dissolving Equipment – Honya Detail:

Five Channel

Introduction

It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis performance. Because the amidite should avoid contacting with the moisture. If the amidite are in the high humidity environment. The synthesis efficiency will be influenced.

The opened reagent and amidite should be dried with molecular trap.

Phosphoramidite Dissolving Equipment new01
Phosphoramidite Dissolving Equipment new00

12 Channel Dissolving Instrument

Specification

1. It suitable for various bottle types, the dissolving volume of the bottle is 0.5-45ml.
2. Configure the number of liquid inlet bottles according to customer needs (the standard volume is 4L reagent bottles), with professional bottle caps, and users can allocate liquid positions by themselves.
3. All pipelines, joints and key positions are made of corrosion-resistant materials.
4. Each bottle is equipped with an independent valve, and the valve adopts the Burkert (German).
5. Add steel needles to the mouth, one for adding liquid, one for exhausting, and one for cleaning steel needles.
6. Each channel works independently.
7. Electronic valve calibration system.
8. There is a waste liquid groove to facilitate the collection of waste liquid when cleaning the steel needle.
9. There is an independent, freely movable acetonitrile pipeline for washing or free liquid injection, the length is 30cm~40cm.

Phosphoramidite
Amidites-Dissolved-Equipment00

And we can also provide the 14 Channel, 18 Channel, and other model according to your requirements.


Product detail pictures:

Factory Outlets Cpg Frit Column - Phosphoramidite Dissolving Equipment – Honya detail pictures

Factory Outlets Cpg Frit Column - Phosphoramidite Dissolving Equipment – Honya detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" will be the persistent conception of our company to the long-term to establish together with customers for mutual reciprocity and mutual gain for Factory Outlets Cpg Frit Column - Phosphoramidite Dissolving Equipment – Honya , The product will supply to all over the world, such as: Montreal, Comoros, Israel, At Present, our merchandise have been exported to more than sixty countries and different regions, such as Southeast Asia, America, Africa, Eastern Europe, Russia, Canada etc. We sincerely hope to establish wide contact with all potential customers both in China and the rest part of the world.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Gemma from Madagascar - 2017.04.08 14:55
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Amy from Jordan - 2017.03.07 13:42
    Write your message here and send it to us