With our outstanding administration, powerful technical capability and strict top quality handle procedure, we go on to provide our purchasers with reliable good quality, reasonable selling prices and excellent services. We goal at becoming certainly one of your most responsible partners and earning your gratification for Caged Fluorescein, Large Scale Modeling Column Paper, Oxi For Oxidation, We also ensure that your choice is going to be crafted with the highest good quality and dependability. Be sure to feel free of charge to contact us for additional information.
100% Original Oligo Purification Protocol - Molecular traps for phosphoramidite and reagents – Honya Detail:

Product Description

In the ABI and MilliGen/PerSeptive DNA synthesis tests, the sub-sieve pack can keep the water content in the nitrile and activator bottles below 10 ppm, without having to worry about the valve or the throttle valve being divided into the sub-sieve. Dust or lint on the packaging bag is clogged. It can be directly used for the dewatering of 500 ml, 1L, 2 L and other solvent bottles, and the sub-sieve pack specifications can also be customized.

The following shows the dynamic dewatering effect of 10 g molecular trap in 500ml, 1L, 4L nitrile samples with different water content.

Molecular Traps2

Compare with import molecular trap

500 ml 197 ppm ACN

Time(h)

0

24

48

72

96

HonyaBio

197

33

16.5

6.5

6

Other Countries

197

43

27

15

15

1 L 143 ppm ACN

Time(h)

0

24

48

72

96

HonyaBio

143

48

32

20

15

Other Countries

142

47

36

23

15

4 L 141 ppm ACN

Time(h)

0

24

48

72

96

HonyaBio

141

95

94

84

73

Other Countries

141

96

95

85

72

Instructions and usage

The molecular trap is vacuum-packed, and it needs to be opened even if it is used, and the seal of the reagent bottle must be ensured during use.
2g sieve for 24 h can reduce 165 ppm water content in 500 ml nitrile to 105 ppm.
5 g sieve for 24 h can reduce 172 ppm water content in 500 ml nitrile to 58 ppm.
10 g sieve 24 h It can reduce 166 ppm water content in 1 L nitrile to 68 ppm.
20 g sub-sieve can reduce 162 ppm water content in 4 L nitrile to 109 ppm for 24 h.

We recommend 2 g subsieve for 50-250ml reagent bottles, 5g for 250-500ml reagent bottles, 10g for 500-1000ml reagent bottles, and 20g for 1000-2000ml reagent bottles.

Assurance

Each sub-screen package undergoes strict quality control during the production process. And it is necessary for customers to check the packaging before use:

First, confirm that the packaging vacuum is intact. Any vacuum leakage or air entry will reduce the performance of the product.

Second, be careful when opening the packaging to prevent the sub-screen packaging film from being scratched, and check whether the film is There is a leak.

Post-use treatment

It is not toxic or harmful, they will be contaminated by chemicals and solvents they come into contact with and should be disposed of as contaminated waste after use.

Model and application

We have previously provided sub-sieve bags in sizes of 2 g, 5 g, 10 g, and 20 g., and other specifications can be customized according to customer needs.

The molecular trap is suitable for long-term exposure to nitrile, and may also be used for acetic acid, ether,acetic ether,butyl acetate , alcohol, isopropanol, methanol, butanol, Phenol, pyridine, hydrochloric acid, nitric acid, phosphoric acid, sulfuric acid, methyl chloride, nitrogen methyl imidazole, etc.

It may not be suitable for long-term exposure to tetrahydrofuran, toluene, methyl formamide (DMF), methyl methyl amide (DMAc), N-methylpyrrolidone (NMP) and other solutions.

Molecular Traps3
Molecular Traps4
Molecular Traps5


Product detail pictures:

100% Original Oligo Purification Protocol - Molecular traps for phosphoramidite and reagents – Honya detail pictures

100% Original Oligo Purification Protocol - Molecular traps for phosphoramidite and reagents – Honya detail pictures


Related Product Guide:

Dependable high-quality and fantastic credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of "quality very first, client supreme" for 100% Original Oligo Purification Protocol - Molecular traps for phosphoramidite and reagents – Honya , The product will supply to all over the world, such as: Guyana, Italy, Mongolia, We've been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying products and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Vanessa from Argentina - 2017.11.11 11:41
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Gemma from Barbados - 2018.09.12 17:18
    Write your message here and send it to us